Heating power estimate
Type the floor area, the ceiling height and the insulation level: you get a rough idea of the heating power needed on a very cold day.
Result
7.8 kWHeating power (order of magnitude)
- In watts
- 7,800 W
- Per m²
- 78 W/m²
- Heated volume
- 250 m³
- G coefficient used
- 1.2 W/(m³·K)
- Temperature difference
- 26 °C
Inputs
- Heated floor area
- 100
- Ceiling height
- 2.5
- Home insulation
- Average (older insulation)
- Wanted indoor temperature
- 19
- Outdoor temperature on a very cold day
- -7
How it is calculated
Volume = floor area × ceiling height.
Result
Heating power (order of magnitude)
- In watts
- 7,800 W
- Per m²
- 78 W/m²
- Heated volume
- 250 m³
How it is calculated
- Volume = floor area × ceiling height.
- Power = volume × G × (indoor temperature − outdoor temperature).
- G comes from the insulation level: 0.6 (very good), 0.8, 1.2, 1.6, 2 (none), in W/(m³·°C).
Example
100 m² with 2.5 m ceilings, average insulation (G = 1.2), 19 °C inside and −7 °C outside: 250 × 1.2 × 26 = 7,800 W, about 7.8 kW.
Good to know
- This is only an order of magnitude, not a sizing study.
- Windows, ventilation, orientation and thermal bridges are not taken into account.
- Before buying a boiler or heat pump, ask a professional for a heat loss study.
When to use it
- Get a first idea before asking for a heat pump or boiler quote.
- Compare the needs of a home before and after insulation work.
- To measure the floor area first, use the Room and floor area calculator.
Frequently asked questions
Which outdoor temperature should I use?
The base temperature is the cold reached on the coldest days in your area. A local installer or the weather service can give it.
Is a bigger heat pump better?
Not always. An oversized heat pump starts and stops often, which can wear it and lower its efficiency.
What lowers the power needed most?
Roof insulation and air tightness often give the biggest gain, as heat rises and draughts carry it away.